Controller Mobile 2 - Installation Manual

Controller Mobile

Description

Akiles Controller Mobile is a Cloud access control system that enables the management of any electric door opener and/or automation system via a connection to Akiles Cloud through a dedicated SIM card.

It is the first Cloud system on the market to feature an integrated backup battery, providing several days of autonomy and ensuring continuous operation and secure access even in the event of a power outage.

Akiles Controller Mobile System

Capabilities

Akiles Controller Mobile is designed to:

Key features

* For building entrance doors, opening will only be possible with a Controller Mobile installed directly on the building entrance door electric door opener.

** Opening in the absence of power supply is not available for motorized shutters or parking doors.

*** Administrators will be notified in the event of a power outage, a particularly useful feature for unattended assets.

Box Contents

Item Preview
x1 Akiles Controller Mobile Controller Mobile
x1 Security key Security key
x1 Opening tool Opening tool
x2 Wall anchors (for 6 mm drill bit) Wall anchors
x2 Self-tapping screws Self-tapping screws
x1 Security fixing screw Security fixing screw

Composition

Device Composition Device Composition Device Composition Device Composition

Technical Specifications

Characteristic Specification
Modes Online (with Internet connection) and offline (without Internet connection)
Mounting Standalone/Wall (optional)
Wall-mounted installation using the wall plate with security screw
Color White RAL 9003
Signaling 1 light indicator (RGBW LED) and 1 acoustic indicator (Buzzer)
Power Supply 12 Vdc ± 15% / 1.5 A (5.5 × 2.1 mm jack or terminal block)
Internal rechargeable battery
Maximum consumption < 1 W
Rechargeable battery 1 Li-ion cell, 1500 mAh capacity
Charging time: 4 hours (0% → 100%)
Protections: overcharge, over-discharge, overcurrent, and short-circuit
JEITA charging profile with temperature protection
Backup time Up to 5 days
Outputs 1 SmartDriver output (Lock/Lock terminals) and 1 relay output (C/NO terminals)
SmartDriver output characteristics Output for direct connection of an electric door opener (Lock/Lock terminals)
Suitable for any electric door opener with a coil impedance between 1 and 100 Ω
Relay switching capacity 30 Vdc (Max. 2 A)
Terminals C (Common) and NO (Normally Open)
VOUT voltage output 12 Vdc ± 15% power output with backup in case of power supply outages
Sensor input For a push button or sensor with potential-free output (dry contact)
Connectivity BT (5.0, 4.x), 4G (CAT-M / IoT-NB)
Nano SIM card included
Firmware updates Over-the-Air (OTA)
Materials ABS V0 and PC
Dimensions 112 x 112 x 28 mm
Weight 230 g
Temperature range 0..+45ºC
Humidity range 10–90% (non-condensing)
IP rating IP20 (indoor use only)
Terminal capacity 0.2 mm² < wire size < 2.5 mm², push-in terminals (screwless)

Light Indicator Signals (RGBW LED)

Device Operating Correctly

Color Blinking Meaning
White No Started, everything OK
White Slow Started, all OK (backup power active)

Action Performed (open)

Color Blinking Meaning
Green Opening performed

Device Startup Type

Color Blinking Meaning
Red No Restart
Red Fast Resetting factory values

Internet Connection Issues

Color Blinking Meaning
Purple 1 No network coverage
Purple 2 Network registration failed
Purple 3 DHCP OK, DNS error
Purple 4 Network registration OK, DHCP OK, DNS OK, connection error
Purple 5 No SIM

BT Connection Issues

Color Blinking Meaning
Yellow 1 No connection received from Gateway
Yellow 2 No connection with Controllers / Cylinders / Roomlocks / Pinpads

Dimensions

Device Dimensions

Terminal Block Nomenclature

Terminal Block Nomenclature
Terminal Description
Lock, Lock Direct connection of an electric door opener
NO, C Relay connections (NO: Normally Open, C: Common)
VOUT 12 Vdc ± 15% power output with backup in case of power supply outages
S Sensor input with dry contact / potential-free output (2 states)
~/+, ~/- 12 Vdc ± 15% power input
JACK 12 Vdc ± 15% power supply input (1.5 A)

Installation Diagrams

Diagram 1: Electrified door + Intercom + Sensor/Button

Installation Diagram 1

The diagram shows the typical connection with:

Diagram 2: Installation of a Controller in parallel with an Intercom System (door station)

Installation Diagram 2

The diagram shows:

In this way, it is possible to have backup in case of power supply outages for the building’s access electrified door.

Important: It is very important to respect the polarity shown in the previous figure (Lock connected to the negative of the other system and the Lock terminal connected to the normally open contact of the existing system’s relay).

Diagram 3: Installation of 2 electric door openers

Installation Diagram 3

The diagram shows:

Considerations:

Considerations Before Installation

Consideration 1: When wiring the Akiles Controller Mobile device to an automation system, such as an intercom monitor or a motorized blind control panel, it is recommended to take a photo of the wiring as it is before installation. This may be useful later, when connecting the device to the automation system.

Installation Considerations

Consideration 2: The wire gauge used to connect the Akiles Controller Mobile device to an electric door opener and/or automation system must be appropriate according to its/their power consumption.

Consideration 3: It is important to place the Akiles Controller Mobile device in a location with good mobile signal, since connectivity to Akiles Cloud is achieved via its own mobile SIM.

Consideration 4: If the Akiles Controller Mobile device needs to provide coverage to other Akiles devices via BT, the distance between them should not exceed 25 m on the same floor, nor should the devices be separated by more than 2 floors, in order to ensure proper wireless coverage.

BT Distance Considerations

Consideration 5: Once the device is installed and properly configured, it is recommended to wait 3 to 5 minutes to allow the device to start correctly, connect to Akiles Cloud, and successfully download the latest available firmware version.

Consideration 6: It is strongly recommended that the installation of this device be carried out by an authorized Akiles electrical installer.

Device Installation

  1. Attach the wall plate at the desired location.
Installation step 1
  1. Make the appropriate connections to the terminals of the wall plate, according to the provided installation diagrams.

Installation step 2 Installation step 2

  1. Make the necessary connections on the device (relays, power supply).

Important: Before proceeding to the next step, make sure that the device’s power supply has been connected. Following this sequence ensures a correct installation of the device.

Installation step 3
  1. Remove the protective battery strip. Note that the device is delivered with a protective battery strip, so to activate the battery, the strip must be removed from the slot marked as (9) in the Composition section.
Remove before use
  1. Insert the device into the wall plate. The wall plate has a metal threaded insert (17). To secure the device to the wall, insert the supplied security screw into the hole marked as (4), so that the assembly is firmly anchored to the wall.
Installation step 5
  1. Verify correct orientation. The front cover must be inserted so that the Akiles logo is readable.
Installation step 6
  1. Final checks in the Admin Panel. In the Devices tab of the Admin Panel, the Controller Mobile should appear with the status Online, rather than “Configuration pending”. The corresponding percentage indicating the charge level of the device’s integrated rechargeable battery should also be displayed alongside the status indicator.
Online status with battery level

Wireless Product Specifications

BT5/BT4 Frequencies (communication with user smartphone): 2400–2483.5 MHz (Max. 10 dBm)

Akiles proprietary protocol frequencies (device-to-device communication): 2400–2483.5 MHz (Max. 20 dBm)

CAT-M / NB-IoT Frequencies:

LTE Power Class:

* Battery Powered

Radiofrequency Exposure Information (Maximum Permitted Exposure)

This device complies with EU requirements regarding the limitation of exposure of the general public to electromagnetic fields in order to protect health. To meet radiofrequency exposure requirements, the equipment must be used at a minimum distance of 20 cm from the user.

Standards and Certifications

CE WEEE

The WEEE symbol (Waste Electrical and Electronic Equipment) indicates that this device and its batteries (if included) must not be disposed of with other household waste.

When the product reaches the end of its useful life, take it to a local waste collection point for safe disposal or recycling.

This product complies with the provisions of the European Radio Equipment Directive (2014/53/EU).

This product also meets the essential requirements of Directive 2011/65/EU (RoHS 2), 2012/19/EU (WEEE), and Regulation (EU) No. 1907/2006 (REACH).

Safety Information

This device contains a rechargeable lithium-ion battery. Read the following recommendations carefully before installing or using the equipment.

Akiles Technologies S.L. is not responsible for damages resulting from improper use, incorrect installation, or failure to comply with the safety recommendations indicated in this manual.

Intended use

Environmental conditions

Handling

Power supply

Internal battery instructions

Storage

Product recycling