Controller - Installation Manual

Controller Standard

Description

Akiles Controller System

Akiles Controller is a device designed to act on any lock and/or electrified automation system: community portals, blinds, parking lots, elevators, main entrances, sliding doors, turnstiles, swimming pools, gyms.

Greater physical security than traditional access control systems. For opening community portals, there is no need to install anything outside the home.

Compatible with traditional opening. Akiles Controller allows you to maintain traditional opening in parallel with Akiles management, whether with a physical key, biometric sensor, proximity card or numeric keypad.

Remote configuration. Akiles Controller allows remote configuration of multiple parameters that improve user experience and facilitate management by administrators. The configuration of opening routines allows that, once the community portal is opened, the elevator descends autonomously without the user having to call it from the App or from the elevator’s own button.

Device Description Device Description Device Description

Technical Data

Characteristic Specification
Modes Online (with Internet connection) and offline (without Internet connection)
Mounting Standalone/Wall (optional)
Color White RAL 9016
Signaling 1 light indicator (RGB LED) and 1 acoustic indicator (Buzzer)
Power Supply 12V AC/DC & 24V DC (Jack 5.5 x 2.1 mm or terminals)
Switching Capacity Relay 1: 230 V AC (max. 5 A). Door opener connection.
Relays 2 and 3: 30 V DC (max 2A). Intercom connection.
Connectivity BT (5.0, 4.x). ADSL/Fiber (Ethernet via router)
Firmware Updates Over-the-Air (OTA)
Material Polished ABS V0
Dimensions 146 x 104 x 25 mm
Temperature Range 0..+45ºC
IP Rating IP20 (indoor use only)
Terminal Capacity 0.2 < mm² < 2.5, push-in terminals (no screw)

Light Indicator Signals (RGB LED)

Color Blinking Meaning
Blue No Started, everything OK
Blue Fast Updating configuration
Blue Slow Updating firmware
Green Opening performed correctly
Red No Restart
Red Fast Restoring factory values
Yellow 1 No connection received from gateway
Yellow 2 No connection with Controllers/ Cylinders/ Roomlocks

Dimensions

Device Dimensions

Terminal Nomenclature

Terminal Nomenclature
Terminal Description
NO1 Normally open contact of relay 1
NC1 Normally closed contact of relay 1
C1 Common contact of relay 1
C2 Common contact of relay 2
NO2 Normally open contact of relay 2
C3 Common contact of relay 3
NO3 Normally open contact of relay 3
CD Call detection (positive)
/CD Call detection (negative)
~/+, ~/- Power supply (input). The device can be powered either through these terminals or through the power jack.
S Sensor input (connect between S and GND). Connect a magnetic sensor to detect the door status or a push button/switch for additional functions.
GND Ground
VLOCK Power output (same voltage as the ~ / + terminal and the positive of the jack)

Installation Diagram

Installation Diagram

The diagram shows the typical connection with:

Considerations Before Installation

Installation Considerations

Before manipulating the intercom connections, it is recommended to take a photograph of the wiring at its corresponding connection terminals. It may be useful later.

Installation Considerations

If you are going to pair 2 devices to communicate via Bluetooth, the separation between them should not exceed 25 m on the same floor, nor should the devices be separated by more than 2 floors, in order to have good wireless coverage.

Bluetooth Distance Considerations

The cable section and power supply amperage must be sized according to the door opener consumption (consult the manufacturer’s data sheet for the door opener model used).

Bluetooth Distance Considerations

Once the installation has been registered on the Akiles servers (via the administration panel) and if the configuration is correct, the system should work perfectly after powering it on.

On a newly installed device, wait one minute after startup before testing the door opening.

It is recommended that the installation of this Akiles access control system be carried out by an electrical installer.

Device Installation

  1. Fix the wall mounting plate in the desired location. Ideally close to the intercom and the door frame, on the lock side. The power supply connection must be possible.
Installation Step 1
  1. Make the appropriate connections on the wall mounting plate terminals according to the installation diagrams provided.
Installation Step 1
  1. Connect power supply.
Installation Step 2
  1. Insert the device into the wall mounting plate until both fit perfectly.
Installation Step 2

Device Operation

Device Operation

App: The app allows remote opening via a smartphone with internet connection, or locally via BT4 / BT5 without internet connection.

Product Wireless Characteristics Information

BT5/BT4 Frequencies: 2400–2483.5 MHz (max 8 dBm)

Radio Frequency Exposure Information (Maximum Permitted Exposure)

This device complies with EU requirements on limiting public exposure to electromagnetic fields in order to protect health. To comply with radio frequency exposure requirements, the equipment must be used at a minimum distance of 20 cm from the user.

Standards and Certifications

CE trash

This product complies with the provisions of the European Radio Equipment Directive (2014/53/EU).

This product also complies with the essential requirements of Directive 2011/65/EU (RoHS 2), 2012/19/EU (WEEE) and EU regulation No. 1907/2006 (REACH).

The WEEE symbol (Waste Electrical and Electronic Equipment) indicates that this device and batteries (if incorporated) should not be disposed of with other household waste.

When the product reaches the end of its useful life, take it to a waste collection point in your area for safe disposal or recycling.